Table 4.2 Data for flux linkage error
ERROR IN FLUX LINKAGE (Wb) WITH DTC ERROR IN FLUX LINKAGE (Wb) WITH FUZZY TIME
0 0 0
18 2.4 1
12 1.5 2
14 1.7 3
13.33 1.733 4
13.33 1.733 10

Figure 4.2 Result for flux linkage when fuzzy logic with duty ratio and DTC were used.
In the analysis, the data in table were used. The flux behavior of the motor used in fuzzy logic together with duty ratio control and DTC for a torque demand of 2.4Wb with an output drive updated at the of rate of 5kHz were used, the ripple flux produced was 4.67Wb (18-13.33)Wb greater and lesser values with just a DTC but in fuzzy logic together with duty ratio control, the ripple was minimized more to 0.667Wb (2.4-1.733)Wb higher and lower values, assumed under shoot in the flux value at the starting point of each voltage sector were neglected